ANSUL 150 Bar INERGEN Systems (ANSUL AUTOMAN II-C Releasing Device, Explosion-Proof, 24 VDC)

Part Number: 31492
Weight (lbs): 26
Part Description: The ANSUL AUTOMAN® II-C Releasing Device consists of a metal enclosure which contains a spring-loaded puncture pin release mechanism, an actuation cartridge, electrical circuitry, and an input/output terminal strip for making electrical connections. The ANSUL AUTOMAN II-C releasing device provides automatic pneumatic actuation of the INERGEN® System. When wired to an AUTOPULSE® Control System, it will provide supervised electric detection and release. It also provides manual actuation using the strike button on the release enclosure and with the optional remote manual cable pull station. When an AUTOPULSE Control System is used, manual actuation is accomplished using an electric manual pull station.

Read More

ANSUL 150 Bar INERGEN Systems (ANSUL AUTOMAN II-C Releasing Device, 24 VDC)

Part Number: 17728
Weight (lbs): 26
Part Description: The ANSUL AUTOMAN® II-C Releasing Device consists of a metal enclosure which contains a spring-loaded puncture pin release mechanism, an actuation cartridge, electrical circuitry, and an input/output terminal strip for making electrical connections. The ANSUL AUTOMAN II-C releasing device provides automatic pneumatic actuation of the INERGEN® System. When wired to an AUTOPULSE® Control System, it will provide supervised electric detection and release. It also provides manual actuation using the strike button on the release enclosure and with the optional remote manual cable pull station. When an AUTOPULSE Control System is used, manual actuation is accomplished using an electric manual pull station.

Read More

ANSUL 150 Bar INERGEN Systems (Inspection/Maintenance Devices – Conversion Adapter, Conversion Adapter, CV98 to CV 90)

Part Number: 426181
Material: Brass (Adaptor)
Weight (lbs): 0,5
Part Description: Adaptor Convertor (converts CV-98 pressure tester to CV-90 valve).  The pressure test assembly consists of a calibrated gauge, adaptor, and handwheel. The assembly is attached to the fill port of the INERGEN® valve. As the handwheel is turned in, the fill port is opened and the pressure is read on the gauge. After verifying the pressure in the cylinder, the handwheel is turned out, closing the fill port, and the assembly can be removed. Two pressure tester convertors are also available. These convertors allow a CV-90 pressure test assembly to be used on a CV-98 valve and also a CV-98 pressure test assembly to be used on a CV-90 valve.

Read More

ANSUL 150 Bar INERGEN Systems (Inspection/Maintenance Devices – Conversion Adapter, CV-90 to CV-98)

Part Number: 423657
Material: Brass (Adaptor)
Weight (lbs): 0,6
Part Description: Adaptor Convertor (converts CV-90 pressure tester to CV-98 valve). The pressure test assembly consists of a calibrated gauge, adaptor, and handwheel. The assembly is attached to the fill port of the INERGEN® valve. As the handwheel is turned in, the fill port is opened and the pressure is read on the gauge. After verifying the pressure in the cylinder, the handwheel is turned out, closing the fill port, and the assembly can be removed. Two pressure tester convertors are also available. These convertors allow a CV-90 pressure test assembly to be used on a CV-98 valve and also a CV-98 pressure test assembly to be used on a CV-90 valve.

Read More

ANSUL 150 Bar INERGEN Systems (Inspection/Maintenance Devices – Pressure Test Gauge)

Part Number: 423923
Material: Cast Zinc Alloy (Handwheel), Brass (Body), Brass (Adaptor) Stainless Steel Case, Laminated Safety Glass Lens (Gauge)
Weight (lbs): 5
Part Description: The Pressure Test Assembly Part No. 423923 for CV-98 valves, is required to properly perform the semi-annual pressure check per NFPA 2001. The pressure test assembly consists of a calibrated gauge, adaptor, and handwheel. The assembly is attached to the fill port of the INERGEN® valve. As the handwheel is turned in, the fill port is opened and the pressure is read on the gauge. After verifying the pressure in the cylinder, the handwheel is turned out, closing the fill port, and the assembly can be removed. Two pressure tester convertors are also available. These convertors allow a CV-90 pressure test assembly to be used on a CV-98 valve and also a CV-98 pressure test assembly to be used on a CV-90 valve.