The data center industry in Jabodetabek continues to expand rapidly.
Industrial areas such as Cikarang, Bekasi, and Tangerang attract major investments.
Data centers require reliable and responsive fire protection systems.
These systems must protect critical IT assets and maintain uptime.
Fire Suppression System and Fire Pump Jockey Data Center solutions play a vital role in this protection strategy.
Role of Fire Suppression System in Data Cente
A Fire Suppression System detects and controls fire risks at an early stage.
It protects server rooms, electrical rooms, and battery rooms.
Stable water pressure in the hydrant network remains essential.
The jockey pump maintains consistent system pressure.
It prevents the main fire pump from activating due to minor pressure drops.
Routine maintenance ensures the system performs during emergencies.

Scope of Work by ODG Nusantara Jaya
ODG Nusantara Jaya has completed multiple Fire Suppression System and Fire Pump – Jockey projects in Jabodetabek data centers.
The team performs Inspect Jockey Pump for General Condition inspections.
They verify suction line pressure and system line pressure conditions.
All light indicators must show normal status.
Technicians check for wear, corrosion, and visible damage.
They conduct Inspect Coupling and Shaft Alignment using precision tools.
They also check pump shaft end play carefully.
Technicians verify Pressure Control Settings according to design specifications.
They inspect all electrical connections for safety and integrity.
The team inspects piping, hoses, and seals for leaks.
No leakage is tolerated within the system.
Safety devices and alarms undergo functional testing.
Pressure sensors and switches are tested for accuracy.
They test the electrical motor and controller thoroughly.
Pressure Relief Valves are inspected and tested properly.
Mechanical parts receive cleaning and lubrication when required.
Performance Monitoring and Operational Testing
Technicians record flow and pressure parameters accurately.
They compare the data with design specifications.
They also test fire pump alarm signals for proper integration.
They check suction pressure gauges and discharge pressure gauges.
All parameters are documented in detailed reports.
The team conducts an Operational Test of Jockey Pump through a flow start test.
This test confirms automatic pump response to pressure drops.
Fire Suppression System and Fire Pump Jockey Data Center maintenance ensures system reliability and compliance.
Commitment to Data Center Reliability
ODG Nusantara Jaya prioritizes safety and system performance.
Each project follows strict technical procedures and industry standards.
Routine maintenance supports maximum uptime and operational continuity.
A well-maintained system reduces the risk of fire-related downtime.
Don’t wait for your fire protection system to become a risk.
Entrust your Fire Suppression System and Fire Pump Jockey Data Center to ODG Nusantara Jaya for meticulous inspection and maintenance.
Contact us now to schedule a technical assessment at your data center location.